Pellematicsettings
77
ThemenuitemAshCleanispresentaftertheactivationofaexternalde-ashingsystemoraburnerplatecleaning
system.TheactivationisonlypossibleafterenteringtheCodeforservicetechnicians.Theexternalde-ashing
systemandtheburnerplatecleaningsystemrunparallel.
Mode
Youactivatethefunctionofanexternalde-ashingsystemandtheburnerplate
cleaningsystem.
0=inactive,1=active—Ifyouhaveanexternalde-ashingsystemandaburner
platecleaningsystem,theyrunparallel.
Beforeeachignitionthede-ashingsystemand/ortheburnerplatecleaningsystem
areactivefor20seconds.
Note
Ifthereisnoburnerdemandlongerthan5days,thede-ashingsystem
activatesitselfonFridayon12:00for3/5minutes.Thispreventsaash
solidicationaroundtheauger.
MInimumRunTime
IstheMinimumRunTimeoftheboileruntilthenextashremovalsequence.Value
adjustable.
DeliveryDuration
Istheruntimeoftheashauger.Valueadjustable.
RunOnTimeRemainingRunTimeoftheboileraftertheerrormessage"ashboxfull"untilit
switchesoffcompletely.
27.7Boilercleaning
BoilercleaningisinthePellematicmenu.
Settheboilercleaningaccordingtoyourrequirements.
•Cleaning/Filling
•Cleaning2
•MinRunTime
•CleaningTime
Seecustomermenu11.6BoilerCleaning,page35