Pellematicsettings
75
27.4RunOnTimesettings
RunOnTimeisinthePellematicmenu.
RunOnTimehasfollowingmenuitems:
•BurnerFanPerformance
•FlueGasFanSpeed
•BurnerFanRunOnTime
•FlueGasFanRunOnTime
•BurnerFan/AGTOff
•FlueGasFan/AGTOff
•BurnerFan/FRTOff
•FlueGasFan/FRTOff
TheadditionalmenuitemsRunOnTimesettingsarefortheÖkoFENServicetechnician.Theyarepresent
afterenteringthecode:
BurnerFanPerformanceAdjustingthespeedoftheburnerfaninthefullpowermodeinpercent.Thespeed
reducescontinuouslyintherunontime.
FlueGasFanSpeedAdjustingthespeedoftheuegasfaninthefullpowermodeinpercent.Thespeed
reducescontinuouslyintherunontime.
BurnerFanRunOnTimeMinimumrunontimeoftheburnerairfanatthemomentofswitchoffinseconds.
FlueGasFanRunOnTimeMinimumrunontimeoftheuegasfanatthemomentofswitchoffinseconds
BurnerFan/AGTOffTheburnerfanrunsaftertheminimumdelaytimehaselapsedevenuntiltheuegas
temperatureislowerthantheboilertemperature+thesettemperaturevalue:
e.g:Boilertemperature=76°C+32°C=108°CSwitchofftemperature.
FlueGasFan/AGTOffTheuegasfanrunsaftertheminimumdelaytimeuntiltheuegastemperatureis
lowerthantheboilertemperature+thesettemperaturevalue:
e.g:Boilertemperature=76°C+12°C=88°CSwitchofftemperature.
BurnerFan/FRTOffTheburnerfanrunsaftertheminimumdelaytimeuntilthecombustionchamber
temperatureislowerthantheboilertemperature+thesettemperaturevalue:
e.g:Boilertemperature=76°C+250°C=326°CSwitchofftemperature.
FlueGasFan/FRTOffTheuegasfanrunsaftertheminimumdelaytimeuntilthecombustionchamber
temperatureislowerthantheboilertemperature+thesettemperaturevalue:
e.g:Boilertemperature=76°C+150°C=226°CSwitchofftemperature.
E1389EN2.0
OperatingmanualPelletronicTouch