Okofen PELLETRONIC TOUCH - Level Detection System Settings

Okofen PELLETRONIC TOUCH
108 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Pellematic
37
11.8Leveldetectionsystem
LeveldetectionsystemisinthePellematicmenu.
Leveldetectionsystemhasthefollowingmenuitems:
•Mode
TextileTank
StorageRoom
CapacitiveSensor
•LimitValue
•CorrectionValue
Adjustthesuctionsystemaccordingtothedemandsofyourheatingsystem.
TextileTank
LeveldetectionsystemusingweighingcellsforFleXILOtextiletanks.
StorageRoom
Leveldetectionsystemusingweighingcellsatthehopperforstoragerooms.(only
forPellematicTypePES36–56)
CapacitiveSensor...Leveldetectionsystemusingacapacitivesensorforstorage
roomsandTextiletanks.
LimitValue
istheminimumweightforawarningmessage.Valueadjustable.Thewarning
messageappearsontheoperatingdeviceanddisappearswhenthellingweightis
abovethesetminimumweight.
ModeChoose:
CorrectionValue
OnlyifmodeFlexiTankorStorageroomischosen.Setthedisplayofthecurrent
weightto0byputtinginthenegativeofthecurrentweightshown
E1389EN2.0