Heatingcircuitssettings
56
Flowrange
Thisfunctiondynamicallyreducestherateatwhichthemixeroperatestoreduce
boilercycling,particularlyusefulwhenstartingsystemswithhighload.
Boilertemperature
smoothing
Theboilertemperaturesmoothingcontrolstheboilerloadbysmoothingtheoperation
ofthemixer.
Note
Theboilertemperaturesmoothingoperatesonlyonsystemswithout
accumulatorandexistingboiler.
Temperaturerise
Theminimumvalueofthetemperatureriseattheboilersensor.
BoilerloadcontrolrangeIsthetemperaturerangewithinthePelletronicmeasures.
MinimumTemp/Risetime
Thisistheminimumtemperatureriserequiredovertherisetime.
1Theboilertemperaturerisesorexceedstheminimumtemperaturewithintheset
risetime.
TheMixeropeningtimeisnotinuenced.
2Theboilertemperatureremainssteadywithinthesetrisetime.
Themixerstaysinthesameposition.
3Theboilertemperaturefallswithinthesetrisetime.
Themixerstartstoclose.
4Theboilertemperaturerisesorexceedstheminimumtemperaturewithintheset
risetime.
TheMixeropeningtimeisnotinuenced.
OperatingmanualPelletronicTouch
E1389EN2.0