Test Programs Maintenance Manual
Test No./
Function Outline
:
FOUP Clamp <FOUP Door latch movement check>
If the loader has not been initialized, initialization starts.
①FOUP Clamp ②FOUP Dock position ③FOUP Door Clamp ④FOUP Door Unclamp
The loader then repeats steps ③ to ④.
・ Do not install the cassette.
・ Press the [Start] button to pause the operation at the break point, and press it again to continue the
operation.
・ When an error occurs, the loader displays the same error code as in the regular operation, and then
stops.
・ Press the [Quit] button, and the FOUP opener returns to its initial position and the loader stops the
operation.
:
Door open, Wafer mapping, Z-axis (vertical) movement <Menu2>
This program can be used to check the operations of Door open, Wafer mapping and Z-axis (vertical)
movement.
[M1]:Door open <FOUP Door open close check>
[M2]:Wafer mapping <Wafer mapping sensor movement check>
[M3]:Z-axis (vertical) movement <Z axis movement check>
:
Door open <FOUP Door open close check>
If the loader has not been initialized, initialization starts.
①FOUP Clamp ②FOUP Dock position ③FOUP Door Clamp ④FOUP Door open
⑤FOUP Door close
The loader then repeats steps ④ to ⑤.
・ Do not install the cassette.
・ Press the [Start] button to pause the operation at the break point, and press it again to continue the
operation.
・ When an error occurs, the loader displays the same error code as in the regular operation, and then
stops.
・ Press the [Quit] button, and the FOUP opener returns to its initial position and the loader stops the
operation.
:
Wafer mapping <Wafer mapping sensor movement check>
If the loader has not been initialized, initialization starts.
① FOUP Door open. ② Press the interlock switch and the [Start] button.
③ Lowers the FOUP Door map start position. ④ Insert the map sensor. ⑤Escape the map sensor.
The loader then repeats steps ④ to ⑤.
・ Do not install the cassette.
・ Press the [Start] button to pause the operation at the break point, and press it again to continue the
operation.
・ When an error occurs, the loader displays the same error code as in the regular operation, and then
stops.
・ Press the [Quit] button, the loader stops the continuous operation. If you press the [Start] button
while pressing the interlock switch of the FOUP opener, the loader returns to its initial position and
stops the operation.