Loading...
Test Programs Maintenance Manual
3-6
Page
Test No./
Test Name
Function Outline
[M4]
FOUP Clamp <FOUP Door latch movement check>
If the loader has not been initialized, initialization starts.
FOUP Clamp FOUP Dock position FOUP Door Clamp FOUP Door Unclamp
The loader then repeats steps to .
Do not install the cassette.
Press the [Start] button to pause the operation at the break point, and press it again to continue the
operation.
When an error occurs, the loader displays the same error code as in the regular operation, and then
stops.
Press the [Quit] button, and the FOUP opener returns to its initial position and the loader stops the
operation.
[M2]
Door open, Wafer mapping, Z-axis (vertical) movement <Menu2>
This program can be used to check the operations of Door open, Wafer mapping and Z-axis (vertical)
movement.
[M1]Door open <FOUP Door open close check>
[M2]Wafer mapping <Wafer mapping sensor movement check>
[M3]Z-axis (vertical) movement <Z axis movement check>
[M1]
Door open <FOUP Door open close check>
If the loader has not been initialized, initialization starts.
FOUP Clamp FOUP Dock position FOUP Door Clamp FOUP Door open
FOUP Door close
The loader then repeats steps to .
Do not install the cassette.
Press the [Start] button to pause the operation at the break point, and press it again to continue the
operation.
When an error occurs, the loader displays the same error code as in the regular operation, and then
stops.
Press the [Quit] button, and the FOUP opener returns to its initial position and the loader stops the
operation.
[M2]
Wafer mapping <Wafer mapping sensor movement check>
If the loader has not been initialized, initialization starts.
FOUP Door open. Press the interlock switch and the [Start] button.
Lowers the FOUP Door map start position. Insert the map sensor. Escape the map sensor.
The loader then repeats steps to .
Do not install the cassette.
Press the [Start] button to pause the operation at the break point, and press it again to continue the
operation.
When an error occurs, the loader displays the same error code as in the regular operation, and then
stops.
Press the [Quit] button, the loader stops the continuous operation. If you press the [Start] button
while pressing the interlock switch of the FOUP opener, the loader returns to its initial position and
stops the operation.