A071 PID Function Enable 00 (disabling), 01 (enabling),
02 (enabling inverted-data output)
–  125Fh 00
A072 PID proportional gain 0 to 2500 0.10  1260h 1.00
A073 PID integral time constant 0 to 36000 0.1 [sec.]  1261h 1.0
A074 PID derivative gain 0 to 10000 0.01 [sec.]  1262h 0.00
A075 PV scale conversion 1 to 9999 0.01  1263h 1.00
A076 PV source 00 (input via OI), 01 (input via O), 02 (external commu-
nication), 03 (pulse train frequency input), 10 (opera-
tion result output)
–  1264h 00
A077 Reverse PID 00 (disabling), 01 (enabling) –  1265h 00
A078 PID output limiter 0 to 1000 0.1 [%]  1266h 0.0
A079 PID feed forward selection 00 (disabled), 01(O input), 02 (OI input) –  1267h 00
A081 AVR function select 00 (always on), 01 (always off), 02 (off during decelera-
tion)
–  1269h 02
A082 AVR voltage select 200 V class: 0 (200)/1 (215)/2 (220)/3 (230)/4 (240
400 V class: 5 (380)/6 (400)/7 (415)/8 (440)/9 (460)/ 10
(480))
–  126Ah -
A083 AVR filter time constant 0.000 to 10.00 0.001[sec]  126Bh 0.300
A084 AVR deceleration gain 50 to 200 1[%]  126Ch 100
A085 Energy-saving operation mode 00 (normal operation), 01 (energy-saving operation) –  126Dh 00
A086 Energy-saving mode tuning 0 to 1000 0.1 [%]  126Eh 50.0
A092 (32-bits) Acceleration time (2) 1 to 360000 0.01 [sec.]  1274h 10.00
1275h
A093 (32-bits) Deceleration time (2) 1 to 360000 0.01 [sec.]  1276h 10.00
1277h
A094 Select method to switch to Acc2/Dec2 profile 00 (switching by 2CH terminal),01 (switching by set-
ting) 02 (Forward and reverse)
–  1278h 00
A095 (32-bits) Acc1 to Acc2 frequency transition point 0 to 40000(100000) 0.01 [Hz]  1279h 0.00
127Ah
A096 (32-bits) Dec1 to Dec2 frequency transition point 0 to 40000(100000) 0.01 [Hz]  127Bh 0.00
127Ch
A097 Acceleration curve selection 0 (linear), 1 (S curve), 2 (U curve),
3 (inverted-U curve), 4 (EL-S curve)
–  127Dh 01
A098 Deceleration curve setting 0 (linear), 1 (S curve), 2 (U curve),
3 (inverted-U curve), 4 (EL-S curve)
–  127Eh 01
A101 (32-bits) [OI] input active range start frequency 0 to 40000(100000) 0.01 [Hz]  1281h 0.00
1282h
A102 (32-bits) [OI] input active range end frequency 0 to 40000(100000) 0.01 [Hz]
 1283h 0.00
1284h
A103 [OI] input active range start current 0 to "[OI]-[L] input active range end current" 1 [%]  1285h 20
A104 [OI] input active range end current "[OI]-[L] input active range start current" to 100 1 [%]  1286h 100
A105 [OI] input start frequency select 00 (external start frequency), 01 (0 Hz) –  1287h 00
A131 Acceleration curve constant 1 (smallest swelling) to 10
largest swelling)
–  12A5h 2
A132 Deceleration curve constant 1 (smallest swelling) to 10
(largest swelling)
-  12A6h 2
A141 Operation-target frequency selection 1 00 (digital operator), 01 (keypad potentiometer), 02
(input via O), 03 (input via OI), 04 (external communi-
cation), 05 (option ), 07 (pulse train frequency input)
-  12AFh 02
A142 Operation-target frequency selection 2 00 (digital operator), 01 (keypad potentiometer), 02
(input via O), 03 (input via OI), 04 (external communi-
cation), 05 (option ), 07 (pulse train frequency input)
–  12B0h 03
A143 Operator selection 00 (addition: A141 + A142), 01 (subtraction: A141 -
A142), 02 (multiplication: A141 x A142)
–  12B1h 00
A145 (32-bits) Frequency to be added 0 to 40000(100000) 0.01 [Hz]  12B3h 0.00
12B4h
A146 Sign of the frequency to be added 00 (frequency command + A145), 01 (frequency com-
mand - A145)
–  12B5h 00
A150 EL-S-curve acceleration/deceleration ratio 1 0 to 50 1 [%]  12B9h 10
A151 EL-S-curve acceleration/deceleration ratio 2 0 to 50 1 [%]  12BAh 10
A152 EL-S-curve deceleration/deceleration ratio 1 0 to 50 1 [%]  12BBh 10
A153 EL-S-curve deceleration/deceleration ratio 2 0 to 50 1 [%]  12BCh 10
A154 (32-bits) Deceleration hold frequency 0~40000(100000) 0.01 [Hz]  12BDh 0.00
12BEh
A155 Deceleration hold time 0~600 0.1 [sec.]  12BFh 0.0
A156 (32-bits) PID sleep function triggering level 0~40000(100000) 0.01 [Hz]  12C0h 0.00
12C1h
A157 PID sleep function action delay time 0~255 0.1 [sec.]  12C2h 0.0
A161 (32-bits) [VR] input active range start frequency 0~40000(100000) 0.01 [Hz]  12C6h 0.00
12C7h
A162 (32-bits) [VR] input active range end frequency 0~40000(100000) 0.01 [Hz]  12C8h 0.00
12C9h
A163 [VR] input active range start % 0~100 1 [%]  12CAh 0
A164 [VR] input active range end % 0~100 1 [%]  12CBh 100
A165 [VR] input start frequencyselect 00(start frequency A161) / 01(0Hz) – 
12CCh 01