Item
Set value
[Factory default]
Description
Username - Enter the user name and the password to access the net-
work drive.
If you do not know the user name or the password, contact
the device network administrator
Password
-
4 Click the Apply button.
Edited information is saved to the Sensor Controller.
It’s information will be available with restarting Sensor Controller.
Precautions for Correct Use
Click Apply after saving or reading of Network drive. If you click it while Network drive is run-
ning, Network drive’s file could be given a damage.
Precautions for Correct Use
If images and data are logged to a network drive, the use of the multi-input function and other
heavy measurement loads on the Controller may slow down communications and cause log-
ging errors. In this case, set the measurement takt time so that there is some leeway.
If many drives are set as network drives, it may require a greater amount of time to start the
Controller.
Do not pull out the LAN cable while the Controller is accessing the network drives.
Start the Controller when the network drives are ready. Connections cannot be established if
the network drives are not ready when the Controller is started.
If there is no access to a network drive for a certain amount of time, the connection will be
automatically cut off depending on the network drive setting at the connection target. Make
sure that the setting at the connection target is not set to automatic disconnection.
Dates and Times of the Updates of the Files Created at Network Logging
If the time zone of the external device is different from the time zone setting of the Controller
GMT-08:00 Pacific Time (US & Canada): Do not automatically adjust clock for Daylight
SavingTime], the date and time actually written may be different from the date and time of the
file update. Adjust the time zone of the external device to match that of the Controller.
For Network drive communication with the FH series/FHV series, you can specify IP address
instead of Host name on the Shared file setting.
For FH series/FHV series, you can set WINS server.
4 Setting the Controller
4 - 54
FH/FHV Series Vision System User’s Manual (Z365-E1)

Table of Contents

Other manuals for Omron fh series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron fh series and is the answer not in the manual?

Omron fh series Specifications

General IconGeneral
BrandOmron
Modelfh series
CategoryMachine Vision Systems
LanguageEnglish

Related product manuals