Item
Setting value
[Factory default]
Description
Data settings - Sets data to display.
Data type
• [Direct input]
• Unit data
• Scene variable
• Global data
• System data
• System variable
Selects the data type for display object.
Data - Set as follows according to the Data type.
Direct input:
Sets the character string to display using up to 128 characters.
Multi-language input is possible.
Other than Direct input:
Setting contents vary depending on the Data type. Up to 32 char-
acters can be input.
(1)
Unit data: External reference number or identifier name
Unit data: Specifies the unit to set data with a unit number or
unit label character string using up to 32 characters. Only
single-byte alphanumeric characters as well as _&#$@ can
be input.
(2) Scene variable/System variable: Variable name
(3) System data/Global data: Identifier name
System data: Selects the system data identifier name 0 from
the combo box. (PanDA or Macro_IO)
Value type
• [String]
• Number
Specifies the data type.
Align
• [Left]
• Center
• Right
Sets the character display position.
8 Setting Windows
8 - 48