EasyManua.ls Logo

Omron FQ2-S4 - Page 134

Omron FQ2-S4
594 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Reading DPM 2D Codes
132
FQ2-S4 User’s Manual
8 Press [Back].
ASCII code table
5 Repeat the above procedure to register more than
one character string in the master data.
6 Press [Verif. master data] and select the character
string in the master data to use for verification.
7 Set the following verification conditions as required.
Parameter Setting Description
Verif. master data OFF (default)
All master data
Master data 0 to 31
Sets whether to verify the read character string against a character string
that is registered in the master data. To verify the read character string
against the master data, select the character string to use for verification.
Master data regist. --- Registers a character string in the master data.
Auto teach No. OFF (default)
Master data 0 to 31
Sets the character string in which to automatically register the read result for
teaching from an external device.
The following table shows the ASCII codes that can be used for manual registration of master data and also
for registering characters of Limits.
Note
Upper 4 bits
Lower 4 bits

Table of Contents