Setting the Retry Function
276
FQ2-S4 User’s Manual
Auto scanning order
The scanning procedure when the sort order is set to auto is shown below.
1st : The immediately previous scene that scanned successfully
2nd and following: Order of largest number of successful scans
In the default state, the order is the order of the scene numbers.
If the power is interrupted or the sensor is restarted, the success counts are initialized when adjust mode is entered.
Setting trigger retry
Set the retry mode to [Trigger retry] in "Retry details".
(Setup Mode) [Sensor settings] [Retry details]
To use trigger retry, the I/O input mode must be set to expanded mode.
[In/Out] [I/O setting] [I/O terminals] [Input] tab [Input mode]
Press "Expanded mode".
1 Press [Trigger retry] for the retry mode.
Scan condition of immediately
previous successful scan
Scene 1
Success count: 25
Scene 1
Success count: 25
Scene 2
Success count: 1
Scene 2
Success count: 1
Scene 3
Success count: 50
Scene 3
Success count: 50
Scene 4
Success count: 15
Scene 4
Success count: 15
Scene 5
Success count: 9
Scene 5
Success count: 9