Outputting Data and Controlling Operation through EtherNet/IP
350
FQ2-S4 User’s Manual
If measurements are executed in parallel, the EtherNet/IP BUSY signal will also turn ON.
RUN Run Mode This signal is ON while the Vision Sensor is in Run Mode. Sensor status
change output
This signal is OFF while the Vision Sensor is not in Run
Mode.
GATE Data Output Com-
pleted
This signal turns ON when the Vision Sensor finishes out-
putting data.
Data output
after measure-
ments
If [Handshake setting] is set to [Yes], this signal automati-
cally turns OFF when the Data Output Request Bit (DSA)
signal from the PLC turns OFF. If [Handshake setting] is
set to [No], this signal turns OFF after the data output
period has elapsed.
Command code Command code This I/O port returns the command code that was exe-
cuted.
Command/
response com-
munications
Response code Response code This I/O port contains the response code of the executed
command.
Response data Response data This I/O port contains the response data of the executed
command.
Signal Signal name Function Application
method