PLC Link Connections
390
FQ2-S4 User’s Manual
Start Continuous Measurements (Command Code: 1020 0010)
Command (PLC to Vision Sensor)
Response (Vision Sensor to PLC)
End Continuous Measurements (Command Code: 1030 0010)
Command (PLC to Vision Sensor)
Response (Vision Sensor to PLC)
First word of
command
area
Bits Contents
12 to 15 8 to 11 4 to 7 0 to 3
+2 0001 0000 0010 0000 Command code
+3 0000 0000 0001 0000
First word of
response area
Bits Contents
12 to 15 8 to 11 4 to 7 0 to 3
+2 0001 0000 0010 0000 Command code
The command code for which the
response applies is stored.
+3 0000 0000 0001 0000
+4 0000 0000 0000 0000 Response code
Command execution result
0: OK, FFFFFFFF: NG
+5 0000 0000 0000 0000
The measurement results are written to the output area if data output is set.
The measurement results are not output if data output is not set.
Setting the Data To Output Automatically after Measurements: p. 377
First word of
command
area
Bits Contents
12 to 15 8 to 11 4 to 7 0 to 3
+2 0001 0000 0011 0000 Command code
+3 0000 0000 0001 0000
First word of
response area
Bits Contents
12 to 15 8 to 11 4 to 7 0 to 3
+2 0001 0000 0011 0000 Command code
The command code for which the
response applies is stored.
+3 0000 0000 0001 0000
+4 0000 0000 0000 0000 Response code
Command execution result
0: OK, FFFFFFFF: NG
+5 0000 0000 0000 0000
Note