EasyManua.ls Logo

Omron FQ2-S4 - Page 396

Omron FQ2-S4
594 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PLC Link Connections
394
FQ2-S4 User’s Manual
Get Image Adjustment Data (Command Code: 1010 0040)
Command (PLC to Vision Sensor)
Response (Vision Sensor to PLC)
Set Image Adjustment Data (Command Code: 1010 0050)
Command (PLC to Vision Sensor)
First word of
command
area
Bits Contents
12 to 15 8 to 11 4 to 7 0 to 3
+2 0001 0000 0001 0000 Command code
+3 0000 0000 0100 0000
+4 0000 0000 0000 0000 Position compensation item/filter
item number
+5 0000 0000 0000 0000
+6 0000 0000 0000 0000 Data number
12-2 External Reference
Parameters p. 491
+7 0000 0000 0000 0000
First word of
response area
Bits Contents
12 to 15 8 to 11 4 to 7 0 to 3
+2 0001 0000 0001 0000 Command code
The command code for which the
response applies is stored.
+3 0000 0000 0100 0000
+4 0000 0000 0000 0000 Response code
Command execution result
0: OK, FFFFFFFF: NG
+5 0000 0000 0000 0000
+6 0000 0000 0000 0000 Acquired data (1,000 times the
value)
+7 0000 0000 0000 0000
First word of
command
area
Bits Contents
12 to 15 8 to 11 4 to 7 0 to 3
+2 0001 0000 0001 0000 Command code
+3 0000 0000 0101 0000
+4 0000 0000 0000 0000 Position compensation item/filter
item number
+5 0000 0000 0000 0000
+6 0000 0000 0000 0000 Data number
12-2 External Reference
Parameters p. 491
+7 0000 0000 0000 0000
+8 0000 0000 0000 0000 Acquired data (1,000 times the
value)
+9 0000 0000 0000 0000

Table of Contents