Controlling Operation and Outputting Data with TCP No-protocol Communications
408
FQ2-S4 User’s Manual
Example: When Data 0 Is 256.324 and Data 1 Is 1.000.
The following range of values can be output.
2,147,483.648 Measured value 2,147,483.647
If the measured value is lower than 2,147,483.648, then 2,147,483.648 is output.
If the measured value is higher than 2,147,483.647, then 2,147,483.647 is output.
The following values are output if JG (Judge) is set.
OK: 0 (0 × 1000)
NG: 1000 (1 × 1000)
Outputting Character Strings
You can set whether to output the character string that results from reading. Outputting the character string is
possible for the following inspection results.
•OCR
Bar code
2D-code
2D-code (DPM)
The procedure for outputting the character string is given here for two inspection items.
[In/Out] [I/O setting] [Output data set] [Noprotocol data output] [Output data set]
1 Select the inspection item for which to output the character string.
2 Set the following items on the setting display.
Binary output does not use data separators, i.e., field separators or record separators. These separators are used
only for ASCII output.
Data that is output after measurement is output until the last data even after the measurement is finished. Data out-
put is not interrupted midway.
Parameter Set value Description
String output ON/OFF No (default)
Ye s
Sets whether to output the character string that results
from reading.
Line delimiter OFF (default)
Comma
Space
Sets the character to use for the line delimiter.
* This setting is enabled only when the OCR inspection
item is selected.
Partial output ON/OFF No (default)
Ye s
Sets whether to specify the range of characters to output.
Output string setup 1 to 128 for OCR
1 to 1024 for Bar code, 2D-
code, or 2D-code (DPM)
Sets the output range.
Data 0: 256324
(256.324 × 1000)
Data 1: 1000
(1.000 × 1000)