Controlling Operation and Outputting Data with TCP No-protocol Communications
FQ2-S4 User’s Manual
425
Connecting through Ethernet
9
Set Inspection Item Text String Data
This command sets the text string data for the specified inspection item.
<Command Format>
<Response Format>
When the Command Is Processed Normally
When the Command Is Not Processed Normally
<Parameter Descriptions>
Inspection item number Specifies the inspection item number. (0 to 31)
External reference data
number
Specifies the external reference data number. (0 to 999)
Refer to 12-2 External Reference Parameters p. 491 for details.
Text string data Specifies the text string data for the specified inspection item.
Refer to 12-2 External Reference Parameters p. 491 for details.
IT DATA2
Text
string data
CR
EM
Inspection
item number
(2 digits max.)
External reference
data number
(3 digits max.)
Command
Space
(0×20)
Space
(0×20)
Space
(0×20)
Delimiter
Text
string data
DelimiterCommand
or
D2I
Inspection item
number
(2 digits max.)
External reference
data number
(3 digits max.)
CR
Space
(0×20)
Space
(0×20)
Space
(0×20)
CR
OK
Delimiter
CR
ER
Delimiter