External Reference Parameters
FQ2-S4 User’s Manual
515
Appendices
12
*1 Use the ITEMDATA2 command to set and/or acquire a text string.
131 Mea-
sure-
ment
result
Code type Settings/
Acquisition
0: Data Matrix
1: QR Code
2: MicroQR Code
3: PDF417
4: MicroPDF417
0 --- ---
132 Timeout time (ms) Settings/
Acquisition
1 to 9999 9999 --- ---
133 Reverse (Data Matrix,
QR Code, Micro QR
Code only)
Settings/
Acquisition
0: Normal
1: Reverse
0 --- ---
134 Code color (Data
Matrix, QR Code, Micro
QR Code only)
Settings/
Acquisition
0: Black
1: White
2: Auto
2 --- ---
135 Shape (DataMatrix
only)
Settings/
Acquisition
0: Square
1: Square or Rect.
0 --- ---
150 Verifica-
tion con-
dition
Selected master num-
ber
Settings/
Acquisition
0 to 31 0 --- ---
152 Auto master data num-
ber
Setting/Acqui-
sition
0 to 31: Master data num-
ber
1: OFF
1 --- ---
170 Output
parame-
ter
String output ON/OFF
(memory link)
Setting/Acqui-
sition
0: OFF, 1: ON 0 --- ---
171 NG error code output
(memory link)
Setting/Acqui-
sition
0: OFF, 1: ON 1 --- ---
172 Partial output ON/OFF
(memory link)
Setting/Acqui-
sition
0: OFF, 1: ON 0 --- ---
173 Output end digit (mem-
ory link)
Setting/Acqui-
sition
1 to 128 128 --- ---
174 Output beginning digit
(memory link)
Setting/Acqui-
sition
1 to 128 1 --- ---
202+3N
(N=0 to
31)
*1
Verifica-
tion con-
dition
Master data N Settings/
Acquisition
32 characters max. None --- ---
300+N
(N=0 to
31)
Reference unit number
N
Setting/Acqui-
sition
0 to 31 0 --- ---
410 Logging
condi-
tions
Data logging switch for
unit
Setting/Acqui-
sition
0: Data logging OFF
1: Data logging ON
1 --- ---
411 Data logging switch for
judgement
Setting/Acqui-
sition
0: Data logging OFF
1: Data logging ON
1 --- ---
412 Data logging switch for
number of characters
Setting/Acqui-
sition
0: Data logging OFF
1: Data logging ON
1 --- ---
500 Display
setting
Number of characters
display
Setting/Acqui-
sition
0: OFF
1: ON
1 --- ---
501 Character display Setting/Acqui-
sition
0: OFF
1: ON
1 --- ---
External
refer-
ence
number
Category Data name Setting/Acqui-
sition
Data range Default Expres-
sion text
string
Logged data/
Judgement
parameter