EasyManua.ls Logo

Omron FQ2-S4 - Page 524

Omron FQ2-S4
594 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
External Reference Parameters
522
FQ2-S4 User’s Manual
400 Verification con-
ditions
Verification master
data
Setting/Acquisition 2: OFF,
1: All master data,
0 to 31: Selected master data
2 --- ---
410 Auto master data
number
Setting/Acquisition 1: OFF,
0 to 31: Selected master data
1 --- ---
500 Selected master
data number
Setting/Acquisition 0 to 31 0 --- ---
700 Similarity display Setting/Acquisition 0: Display, 1: Do not display 0 --- ---
701 Stability display Setting/Acquisition 0: Display, 1: Do not display 0 --- ---
703 Character display Setting/Acquisition 0: Display, 1: Do not display 0 --- ---
1001 Reference unit
number 0
Setting/Acquisition 1: OFF,
0 to 31
1 --- ---
1002+N
× 2 (N = 0
to 3)
Verification end
digit 0N
Setting/Acquisition 1 to 32 32 --- ---
1003+N
× 2 (N = 0
to 3)
Verification begin-
ning digit 0N
Setting/Acquisition 1 to 32 1 --- ---
1011+N
× 2 (N = 0
to 3)
*1
Master data 0N Setting/Acquisition 32 characters max. --- ---
1021 Reference unit
number 1
Setting/Acquisition 1: OFF,
0 to 31
1 --- ---
1022+N
× 2 (N = 0
to 3)
Verification end
digit 1N
Setting/Acquisition 1 to 32 32 --- ---
1023+N
× 2 (N = 0
to 3)
Verification begin-
ning digit 1N
Setting/Acquisition 1 to 32 1 --- ---
1031+N
× 2 (N = 0
to 3)
*1
Master data 1N Setting/Acquisition 32 characters max. --- ---
External
refer-
ence
number
Category Data name Setting/Acquisition Data range Default Expres-
sion text
string
Logged
data/
Judge-
ment
parame-
ter

Table of Contents