APPENDICES
A-4
APPENDICES
Approved Standards
* CE marking does not apply to the USB cable.
Approved safety
standards
cULus (Listing): UL508/CSA C22.2 No. 14
EMC (*)
(EMI) EN61326
Emission Enclosure: EN55011 Group1 Class A
(EMS) EN61326
Immunity ESD: EN61000-4-2: 4 kV contact discharge
8 kV air discharge
Immunity RF-interference: EN61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz
to 1 GHz)
10 V/m (Pulse-modulated, 900 MHz
± 5 MHz)
Immunity Conducted Disturbance EN61000-4-6: 10 V (0.15 to 80 MHz)
Immunity Burst: EN61000-4-4: 2 kV for power-line
1 kV for I/O signal-line
Immunity Surge: EN61000-4-5: 1 kV line to line (power line)
2 kV line to ground (power line)