3.1 Operation Basics
3-3
HOW TO USE THE
BASIC FUNCTIONS
● Operation Modes and Functions
* The items in Italic are explained in "4 HOW TO USE THE ADVANCED FUNCTIONS".
Operation
mode
Display Outline Main functions
Programming
Mode
[PRG] lights. In this mode, programming
and setting, e.g. writing cam
programs and setting the
advance angle compensa-
tion (ADV) function, are per-
formed.
No outputs will be given in
this mode.
• Writing cam programs
(manual/teach)
• Clearing cam programs
• All clear
• Setting the origin
• Setting the advance
angle compensation
(ADV) function
• Switching to the func-
tion setting mode
Test Mode [TST] lights. In this mode, programming
and setting, e.g. writing cam
programs and setting the
advance angle compensa-
tion (ADV) function, are per-
formed while confirming the
outputs. This mode should
also be selected for making
adjustments such as chang-
ing the settings while run-
ning the Cam Positioner.
• Writing cam programs
(manual/teach)
• Clearing cam programs
• All clear
• Setting the origin
• Setting the advance
angle compensation
(ADV) function
Run Mode [RUN] lights. In this mode, normal opera-
tion is performed.
Programming and setting
operations such as writing
cam programs and setting
the advance angle compen-
sation (ADV) function are not
possible.
• Checking cam programs
• Switching the display
between Speed and
Angle
• All protection

Table of Contents