Appendices
A - 26
NX-series Data Reference Manual (W525)
Some support functions of the CPU Units are restricted depending on the models of the NX Units and
unit versions.
The following is a list of restrictions on NX Units for the functions.
When you use the functions of the CPU Units shown below in the NX Units, use the NX Units with the
unit versions or the later unit versions shown in the models of the NX Units and unit versions.
Note that the following tables do not show whether your NX Unit can be connected to the CPU Unit.
Refer to A-5-1 Relationship between Unit Versions of Units on page A-19 for the connection
specifications.
Also, refer to the software user's manual of the CPU Unit for details on the functions listed below.
The following is a list of restrictions for NX Units categorized by type.
NX Unit Part 1
NX Unit Part 2
A-5-2 Support Functions of the CPU Units and Restrictions on the NX
Units
Function of CPU Unit
Models of NX Units and unit versions
Digital
I/O Units
Analog
Input
Units/An
alog Out-
put Units
Tempera-
ture
Input
Units
Position
Interface
Units
System
Units
Restarting Restarting a specified NX Unit Ver.1.0 Ver.1.0 Ver.1.1 Ver.1.1 Ver.1.0
Monitoring total power-ON time Ver.1.0 Ver.1.0 Ver.1.1 Ver.1.1 Ver.1.0
Restarting after trans-
ferring Unit operation
settings
Restarting the NX Unit to which the
Unit operation settings were trans-
ferred when you transfer the settings
to a specified NX Unit
Ver.1.0 Ver.1.0 Ver.1.1 Ver.1.1 Not sup-
ported
Function of CPU Unit
Models of NX Units and unit versions
Safety
Control
Units
Commu-
nica-
tions
Interface
Units
Load
Cell
Input
Units
Heater
Burnout
Detec-
tion
Units
IO-Link
Master
Unit
Restarting Restarting a specified NX Unit Not sup-
ported
Ver.1.0 Ver.1.0 Ver.1.0 Ver.1.0
Monitoring total power-ON time Not sup-
ported
Ver.1.0 Ver.1.0 Ver.1.0 Ver.1.0
Restarting after trans-
ferring Unit operation
settings
Restarting the NX Unit to which the
Unit operation settings were trans-
ferred when you transfer the settings
to a specified NX Unit
Not sup-
ported
Ver.1.0 Ver.1.0 Ver.1.0 Ver.1.0

Table of Contents

Other manuals for Omron NX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron NX Series and is the answer not in the manual?

Omron NX Series Specifications

General IconGeneral
Programming LanguagesLadder, Structured Text, Function Block Diagram, Sequential Function Chart
Communication PortsEthernet, USB, RS-232C, RS-485
Memory CapacityVaries by model
Program MemoryVaries by model
Data MemoryVaries by model
Operating Temperature0°C to 55°C
Power Supply24 VDC
Ethernet Ports1 or 2 ports (depending on model)
USB Ports1 or 2 ports (depending on model)
DimensionsVaries by model
WeightVaries by model