Fault display Possible cause/corrective actionsContents
OL2 (Inverter Overload)

Inverter overload protection op-
erates because of electronic
overload thermal.
Correct load size, operation pattern or V/f set
value. Recheck the inverter capacity.
OL3 (Overtorque Detec-
tion)

Motor current exceeding set
value is applied because of ma-
chine fault or overload.
Check the machine using status and remove
the cause. Or increase the set value up to
the allowable value.
EF3 (External Fault)

Inverter accepts fault contact
signal input from external cir-
cuit.
Check the external circuitry (sequence).
CPF (Control Function
Fault)

-

,

(see note 1)
Inverter control functions are
broken down.
Turn off the power supply once and then turn
it on again. If the fault still exists, replace the
inverter.
CPF-00

(

)
Initial memory fault is detected. Turn off the power supply once and turn it on
again. If the fault still exists, replace the in-
verter.
CPF-01

(

)
Transmission error or ROM
fault is detected.
Turn off the power supply once and turn it on
again. If the fault still exists, replace the in-
verter.
CPF-04

(

)
Constant fault is detected. Record all data, and then make initialization.
Turn off the supply once and turn it on again.
If the fault still exists, replace the inverter.
CPF-05

(

)
AD converter fault is detected. Turn off the power supply once and turn it on
again. If the fault still exists. replace the in-
verter.
CPF-07

(

)
Thermistor fault is detected. Replace the inverter.
Note 1. Digital operator display contents
2. Details of
 
-
::
display. Display in ( ) belongs to the digital dis-
play section.
1-7-2 Alarm Display and Self-diagnosis
Fault display Contents Possible cause/corrective actions
EF (Simultaneous Input of
FWD and REV com-
mands)

blinks.
Both FWD and REV commands
are “closed” for 500 ms or
more.
Check the sequence circuit
BB (External Baseblock)

External baseblock signal is ac-
cepted. (Pay attention since op-
eration restarts by releasing the
external baseblock signal.)
Check the sequence circuit
UV (Main Circuit Under-
voltage)

blinks.
Main circuit DC voltage is re-
duced less than detection level
when inverter is not outputting.
Check power supply voltage or check that
power supply terminal screws are tightened
well.
OL3 (Overtorque Detec-
tion)

blinks.
Inverter output current exceeds
overtorque detection level.
Check the machine using status and remove
the cause. Or increase the set value.
   