EasyManua.ls Logo

Omron Sysdrive RX Series - Page 236

Omron Sysdrive RX Series
442 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-127
4-3 Functions When Option PG Board (3G3AX-PG01) Is Used
4
Functions
Configuration Example
•Main motor : Number of encoder pulses = 1024
•Sub motor : Number of encoder pulses = 3000
•Main motor rpm:Sub motor rpm = 2:1
For operation under the above conditions, set the following data in the slave Inverter.
Electronic gear setting position selection (P019) : 01 (REF)
Electronic gear ratio numerator (P020) : 3000
Electronic gear ratio denominator (P021) : 1024 × 2 = 2048
G
Position loop gain
ASR
REF
FB
-
N
D
FFWG
+
+
+
Electronic gear setting position =00(FB) selected
Position control
feedforward gain
G
Position loop gain
ASR
REF
FB
-
N
D
FFWG
+
+
+
Electronic gear setting position =01(REF) selected
Position control
feedforward gain

Table of Contents