4-127
4-3 Functions When Option PG Board (3G3AX-PG01) Is Used
4
Functions
Configuration Example
Main motor : Number of encoder pulses = 1024
Sub motor : Number of encoder pulses = 3000
Main motor rpm:Sub motor rpm = 2:1
For operation under the above conditions, set the following data in the slave Inverter.
Electronic gear setting position selection (P019) : 01 (REF)
Electronic gear ratio numerator (P020) : 3000
Electronic gear ratio denominator (P021) : 1024 × 2 = 2048
G
Position loop gain
ASR
REF
FB
-
N
D
FFWG
+
+
+
Electronic gear setting position =00(FB) selected
Position control
feedforward gain
G
Position loop gain
ASR
REF
FB
-
N
D
FFWG
+
+
+
Electronic gear setting position =01(REF) selected
Position control
feedforward gain