Page #293 background imageLoading...
Page #293 background image
2-257
2 Instructions
CP1E CPU Unit Instructions Reference Manual(W483)
Data Control Instructions
2
PIDAT
Data Control Instructions
PIDAT
Applicable Program Areas
Operands
C: First Parameter Word
Instruction Mnemonic Variations
Function
code
Function
PID CONTROL WITH
AUTOTUNING
PIDAT --- 191
Executes PID control according to the specified
parameters. The PID constants can be autotuned.
Symbol
PID
Area Step program areas Subroutines Interrupt tasks
Usage OK OK Not allowed
Operand Description Data type Size
S Input word UINT 1
C First parameter word WORD 41
D Output word UINT 1
S: Input word
C: First parameter word
D: Output word
PIDAT(191)
S
C
D
15 8 07
C+5
0
32
14
C
C+1
C+2
C+3
C+4
015
C+6
81112131415
000
0347
Set value (SV)
Proportional band (P)
Integral constant (Tik)
Derivative constant (Tdk)
Sampling period(Ï„)
Forward/reverse designation
PID constant update timing designation
Manipulated variable output setting
Output range
Integral and derivative unit
Input range
Manipulated variable output limit control
2-PID parameter(α)
C+7
C+8
015
C+11
C+40
C+9
C+10
015
015
1214 13
0 0 0
Limit-cycle Hysteresis
Manipulated variable output lower limit
Manipulated variable output upper limit
Work area
(30 words: Cannot be used by user.)
AT Calculation Gain
AT Command Bit

Table of Contents

Other manuals for Omron SYSMAC CP Series