System Errors
Error
code
Name Description
92
Antenna power supply
voltage error
The voltage supplied to the Read/Write Head from the ID Controller has dropped.
• Prepare a replacement ID Controller.
93 Memory error
A memory may have occurred in the ID Controller or noise may have caused an error.
• Reset the power supply.
• Turn ON the RESET input.
• Use the SP command to reset communications with the Data Carrier. (Prepare a
replacement if normal communications cannot be recovered.)

Other manuals for Omron V600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron V600 Series and is the answer not in the manual?

Omron V600 Series Specifications

General IconGeneral
Operating Frequency13.56 MHz
Supported StandardsISO 15693, ISO 18000-3
Read RangeUp to 70 mm (depending on tag and environment)
Power Supply24 VDC ±10%
Operating Temperature-10 to 55°C (with no icing or condensation)
Humidity35% to 85% (non-condensing)
Communication InterfaceRS-232C