158
Section 7 Characteristics According to Application Conditions
RFID System
Operation Manual
Section 7
Appendix
Data Carrier Speed
Use Auto Command and Polling Commands to communicate with moving Data Carriers.
The maximum speed of Data Carrier when executing these commands can be calculated simply using
the following formula.
D can be obtained from the communications area diagram between the Read/Write Head and Data
Carrier or actually measured.
Max. Data Carrier speed =
D (Distance traveled in the transmission range (m))
T (Data Carrier communications time)
Safety factor (0.5)
X
Y
Y
X
Unit: mm
D
Travel direction
Communications area