78
Section 5 Command Format
RFID System
Operation Manual
Section 5
Communications
For Expansion Commands, any command longer than 271 characters or any response longer than 256
characters is divided into multiple frames for communications. Only the last frame is sent with a
terminator (*CR); all other frames are sent with a delimiter (CR).
1. Responses Longer than 256 Characters (EXPANSION READ Command)
When the ID Controller sends a response frame that is not the last frame, the host device returns a
delimiter (CR). When the ID Controller receives the delimiter, it sends the next response frame.
2. Commands Longer than 271 Characters (EXPANSION WRITE Command)
When the ID Controller receives a command frame that is not the last command frame, it returns a
delimiter (CR) to the host device. The ID Controller can then receive the next command frame.
3. For the EXPANDED READ Command, responses for any command reading more than 240 charac-
ters are divided into multiple frames as shown below. Only the last frame is sent with a terminator
(*CR); all other frames are sent with a delimiter (CR).
Response frames are sent with a 20 ms (default) interval between them.
The send interval can be changed with the SET PARAMETER (SP) command.
Command
Host device
ID Controller
Delimiter: CR
Response
Header: XR
Text
Terminator
Delimiter
Delimiter
Text
Terminator
Text
Delimiter
Header: XR
Text
Delimiter
Command
Host device
ID Controller
Delimiter: CR
Response
Delimiter
Header: XW
Text
Terminator
Text
Terminator
Text
Delimiter
Header: XW
Text
Delimiter
Delimiter
Command
Host device
ID Controller
Delimiter: CR
Text
Terminator
Header: ER
Text
Terminator
Text
Delimiter
Text
Delimiter
20 ms
Header: ER
Text
Delimiter

Other manuals for Omron V600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron V600 Series and is the answer not in the manual?

Omron V600 Series Specifications

General IconGeneral
Operating Frequency13.56 MHz
Supported StandardsISO 15693, ISO 18000-3
Read RangeUp to 70 mm (depending on tag and environment)
Power Supply24 VDC ±10%
Operating Temperature-10 to 55°C (with no icing or condensation)
Humidity35% to 85% (non-condensing)
Communication InterfaceRS-232C