TABLE 6-19. TROUBLESHOOTING ENGINE PRIMARY SYSTEMS
Trouble Possible Cause Corrective Action Section/
Page
Engine Shuts 1. Low oil level. 1. Add oil as required.
Down and Will
Not Restart 2. Low oil level switch is defective 2. Check low oil level switch.
(Spec A-F, if applicable).
(Also see 3. Worn spark plug. 3. Clean or replace spark plug.
Control
Trouble- 4. Faulty fuel system - flooded. 4. Refer to
Gasoline Fuel System.
8-11
shooting
table 6-4) 5. Choke not opening. 5. Check choke operation. 8-17
6. Faulty ignition system. 6. Check for spark. 8-6
Engine Runs 1. Fouled spark plug. 1. Clean or replace spark plug.
On After 2. Engine carbon build-up. 2. Remove carbon from engine.
Shutdown

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Onan MicroLite 4000 Series and is the answer not in the manual?

Onan MicroLite 4000 Series Specifications

General IconGeneral
Fuel TypeGasoline
Frequency60 Hz
Rated AC Output4000 Watts
AC Voltage120V
Rated AC Amperage33.3A
Engine TypeOHV
Starting MethodElectric
Noise Level68 dB at 23 ft

Related product manuals