1000 SERIES TURBINE METER CONFIGURATION UTILITY AND INSTALLATION GUIDE
ONICON Incorporated 727.447.6140 Page 29 onicon.com
Total Bottom Turbine Pulses (Read Only)
This value displays the total number of bottom turbine pulses measured since the
meter has been operational. A bottom turbine pulse occurs when a blade of the
bottom turbine passes the bottom electrode while the meter is submerged in a
conductive medium.
Peak Average Turbine Pulses (Read Only)
This value displays the largest average turbine pulse speed (Hz) measured by the
turbine meter at any point during its operation.
Peak Top Turbine Pulses (Read Only)
This value displays the largest top turbine pulse speed (Hz) measured by the
turbine meter at any point during its operation.
Peak Bottom Turbine Pulses (Read Only)
This value displays the largest bottom turbine pulse speed (Hz) measured by the
turbine meter at any point during its operation.
3.3.9 STATUS
The status tab displays the current state of errors, warnings, and alarms present
on the turbine meter. Any errors, alarms, and warnings will automatically
disappear once their cause has been resolved.
Status tab