7.3. Scan Area and Resolution
7.3.1. Depth of Field
The depth of field is measured from the edge of the scanner. The scanning range
is within the circular arc centered on the scan origin.
Figure 3: Depth of field
Symbology Resolution Decode Depth (mm) PCS
Code 39 1.0 mm 40–500 0.9
Code 39 0.5 mm 20–350 0.9
Code 39 0.25 mm 20–200 0.9
Code 39 0.15 mm 20–100 0.9
Code 39 0.127 mm 30–70 0.9
Conditions
Barcode Sample: OPTOELECTRONICS Test Sample
N/W Ratio: 1:2.5
Angle: α = 0°, β = 15°, γ = 0°
Curvature: R = ∞