7.5. Curvature
With 8-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when
R = 15 mm.
With 13-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when
R = 20 mm.
Figure 7: Curvature
Conditions
Barcode Sample: OPTOELECTRONICS Test Sample
PCS = 0.9, Resolution = 0.26 mm, Quiet Zone = 10 mm
Distance: 70 mm from the front edge of the scanner
Angle: Skew Angle β = +15°
8. Interface Specifications
8.1. RS-232C Interface
8.1.1. Settings and Communication
Reading the menu barcodes in section 10.1 can set the RS-232C interface
default.
Item [U2] setting
Baud rate 9600 bps
Start/stop bits 1 bit
Data bits 8 bits
Parity bits No parity
Handshaking No handshake
Flow control time out Indefinitely
You can change the communication condition using the menu barcode.