Opticon
OPR 2001
Specifications Manual
34
13. Durability
13.1. Electrical Noise
No malfunction occurred when sinusoidal electrical noise (10 Hz–100 kHz, < 0.1 Vp-p)
was added to the power supply line.
Conditions
Barcode Sample: OPTOELECTRONICS Test Sample
PCS: 0.9
Resolution: 0.25 mm
Symbology: 9-digit Code-39
Quiet Zone: 10 mm
N/W Ratio: 1:2.5
Distance: 90 mm
Angle: α = 0° β = 15° γ = 0°
Curvature: R = ∞
Power Supply Voltage: 5.0 V
13.2. Static Electricity
Air discharge: ±10 kV max. (No malfunction)
±15 kV max. (No destruction)
Measurement
environment:
Use electrostatic testing device compliant with IEC 61000-4-2
Built up and discharged 15 kV of static electricity on the
scanner surface 50 times.
Discharge resistance: 330 Ω
Capacitor charging: 150 pF