Opticon
OPR 2001
Specifications Manual
35
13.3. Shock
13.3.1. Drop Test (without packaging)
No malfunction occurred after the following drop test.
Drop Test: Drop the scanner from a height of 150 cm onto a concrete floor three
times on each of 5 sides.
Figure 25: Drop test
13.3.2. Drop Test (with individual packaging)
No malfunction occurred after the following drop test.
Drop Test: Drop the scanner from a height of 150 cm onto a concrete floor on
each of one corner, three edges, and six sides (10 drop tests in total)..
13.4. Vibration Strength
No malfunction occurred after the following vibration test.
Vibration test: Increase the frequency of the vibration from 12 Hz to 100 Hz with
accelerated velocity 19.6 m/s
2
(2 G) for 60 minutes in non-operating state. Repeat this
routine in each X, Y, Z direction once for 60 minutes each.
13.5. Dust and Drip Proof
IEC IP42
Dust Prevention
Level Details
4 Prevention of objects larger than 1 mm. Most wires, screws, etc.
Water Prevention
Level Details
2
Vertically dripping water shall have no harmful effect when the enclosure is tilted at an angle up
to 15° from its normal position.