EasyManua.ls Logo

Optoma HD710 - Page 45

Optoma HD710
91 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HD71/HD710/HD75 Condential
4-6
4. Dead Pixel (Bright pixel)
Procedure - Test equipment: video generator.
- Test signal: analog 1280 x 720@60Hz
- Test Pattern: full black
Inspection item - Bright pixel check.
Note: Frame dimension under operative zone
1 inch
Criteria - Bright pixel is unacceptable.
- Ref. below table
Note: The defect criteria follows TI specication.
5. Dead Pixel (Dark pixel)
Procedure - Test equipment: video generator.
- Test signal: analog 1280 x 720@60Hz
- Test Pattern: full white
Inspection item - Dead pixels check.
- White pattern (IRE=100)
- Adjacent dark pixel.
Criteria - The number of the dead pixels should be less or
equal to 6 pixels.
- Adjacent pixel with each other is unacceptable.
- Ref. below table
Note: The defect criteria follows TI specication.
Full black
Full white

Related product manuals