48 Sun SPARC Enterprise T5140 and T5240 Servers Installation Guide • December 2010
If your network does not use DHCP, the network management port is not operational
until you configure network settings for the service processor. Configure the service
processor in this order:
1. After the service processor boots, access the ILOM CLI through the serial
management port. See “Log Into the Service Processor Using the Serial
Management Port” on page 49.
2. Configure the service processor. See “Configure the Service Processor Network
Management Port” on page 50.
3. Commit the changes to the service processor parameters. See Step 3 in “Configure
the Service Processor Network Management Port” on page 50.
You can now use the network management port at any time to access the service
processor.
Related Information
■ “Logging Into the Service Processor” on page 49
Properties:
commitpending = (Cannot show property)
dhcp_server_ip = 10.8.31.5
ipaddress = 10.8.31.188
ipdiscovery = dhcp
ipgateway = 10.8.31.248
ipnetmask = 255.255.252.0
macaddress = 00:14:4F:7E:83:4F
pendingipaddress = 10.8.31.188
pendingipdiscovery = dhcp
pendingipgateway = 10.8.31.248
pendingipnetmask = 255.255.252.0
state = enabled
Commands:
cd
set
show