Return the Server to the Normal Rack Position
If the server is in the extended maintenance position, use this procedure to return the server to
the normal rack position.
1. Push the server back into the rack, as described in the following steps.
a. Simultaneously pull and hold the two green release tabs (one on each side of the slide
rails on the server) toward the front of the server, while you push the server into the
rack.
Verify that the cable management arm (CMA) retracts without binding.
Note:
To pull the green release tab, place your finger in the center of the tab, not on
the end, and apply pressure as you pull the tab toward the front of the server.
b. Continue pushing the server into the rack until the slide rail locks (on the front of the
server) engage the slide rail assemblies.
You hear an audible click when the server is in the normal rack position.
2.
3. If the CMA is not installed, because you removed the server completely out of the rack,
install the CMA.
For installation instructions for the CMA, see Install the Cable Management Arm.
4. If the cables are disconnected from the back of the server, because you extended the
server out of the rack, reconnect the cables. For instructions to reconnect cables to the
back of the server, see Reconnect Power and Data Cables.
Chapter 4
Returning the Server to Operation
4-29