15. Return the storage controller to the rack. As you push the storage controller into
the rack, verify that the CMA retracts without binding.
16. Open the CMA cable covers, route controller cables through the CMA's cable
troughs, close the cable covers, and secure the cables with the six Velcro straps.
Route the cables through the cable troughs in this order: Route the cables through
the front-most cable trough, then through the small cable trough, then through the
rear-most cable trough.