Powering On the Appliance
This section contains power-on procedures for Oracle ZFS Storage Appliance disk shelves and
storage controllers.
Caution - Do not power on disk shelves and controllers until all other cabling is complete, as
described in “Cabling the Appliance” on page 115.
Follow these steps to power on the appliance:
1. Power on disk shelves using the appropriate procedure:
■
“How to Power On a DE2-24 Disk Shelf” on page 119
■
“How to Power On a Sun Disk Shelf” on page 120
2. Power on controllers. See “How to Power On a Controller” on page 121.
Use the following procedures to power off the appliance:
■
“How to Power Off a Disk Shelf” on page 121
■
“How to Power Off a Controller” on page 122
How to Power On a DE2-24 Disk Shelf
Use the following procedure to power on a DE2-24C or DE2-24P disk shelf.
Before You Begin
Ensure you have met the following electrical safety measures before applying power to the disk
shelf:
■
Provide a suitable power source with electrical overload protection to meet the power
supply input voltage range of 100-240 VAC, 50-60 Hz. The disk shelves are compatible
with 100-120 VAC or 200-240 VAC sources. The power source must not be overloaded by
the total number of disk shelves in the cabinet. At full load, each DE2-24 draws 707.8W.
■
The power source must provide a reliable earth connection for each disk shelf and the
cabinet.
■
Ensure that the power source is easily accessible because the power cord is the main
disconnect device for the disk shelf.
Powering On the Appliance 119