3600 Analyzer for O
2
Measurement—Operator’s Manual 69
3600O2.OM.E9903
Index
Instrument LCD message entries in bold
Illustration entries in italics
A
air oxygen sensor calibration........................................12
alarm outputs.................................................................21
alarm configurations................................................21
alarm relay responses ...............................................21
description................................................................21
options menu ............................................................20
wiring identification.................................................51
ammonia cleaning..........................................................30
analog outputs...............................................................22
O
2
concentration output signal................................22
options menu ............................................................21
output conversion.....................................................54
pressure output signal..............................................23
range output signal...................................................23
temperature output signal........................................23
wiring identification.................................................51
analyzer components.......................................................5
arrow keys........................................................................8
ATTENTION HIGH LIMIT.......................................11
ATTENTION LOW LIMIT........................................11
autoranging display mode......................................10, 18
B
battery replacement........................................................54
Binder connector....................................................44, 49
C
cable gland wiring instructions.....................................52
cable glands....................................................................52
cable requirements.........................................................52
calibration......................................................................12
external pressure sensor...........................................14
hydrogen compensation for oxygen sensor.............16
instrument barometric pressure...............................12
oxygen sensor
direct ....................................................................14
in air.....................................................................12
calibration menu............................................................12
calibration menu flow chart..........................................9
CALIBRATION OUT OF BOUNDS................13, 14
check instrument connections.........................................6
check instrument mounting.............................................6
check sensor placement...................................................7
check the oxygen sensor..................................................6
CHECK THE SENSOR.............................................11
check the voltage and line power....................................6
chemical cleaning ......................................................... 29
ammonia cleaning.................................................... 30
nitric acid cleaning................................................... 30
CO
2
/H
2
S insensitivity................................................... 26
components......................................................................5
connectors...............................................................50–51
alarm output............................................................. 51
Binder connector ...............................................44, 49
cable gland wiring instructions............................... 52
external pressure sensor .......................................... 50
LEMO connector assembly instructions ................ 52
oxygen sensor........................................................... 50
recorder (analog) output ......................................... 51
RS-232 (serial) output............................................ 50
D
data acquisition software ..........................see moca3600
direct oxygen sensor calibration.................................. 14
display ranges................................................................ 19
display units option...................................................... 18
dissolved ............................................................18, 19
fraction...............................................................18, 19
partial pressure...................................................18, 19
dissolved display units.................................................. 18
E
electrochemical cleaning.............................................. 29
electromagnetic compatibility (EMC) standards ...........2
ENTER key......................................................................8
ESC key............................................................................8
external pressure sensor
calibration................................................................ 14
input wiring identification...................................... 50
installation............................................................... 59
F
flow chamber installation............................................. 56
flow chamber mounting .............................................. 57
fraction display units.................................................... 18
fuse replacement........................................................... 54
G
gas to measure option................................................... 26
general alarm................................................................. 20
H
H
2
compensation option............................................... 25
high limit....................................................................... 20