Parameter Unit Value
System Type N/A OTRx4
System Band N/A Ku
POINT
G BUC Power Watts 20.0
G BUC Power (P1dB) dBm 43.0
BUC Gain (Nominal) dB 70.0
BUC Internal Attenuation dB -12.0
F Derived Input power to BUC for P1dB dBm -15.0
C to D, E to F Total Pedestal Attenuations: Cables (L-Band cables and Mux cable) + Rotary Joint dB -7.8
C Derived Input power to Pedestal for BUC P1dB (Mux) dBm -7.2
Tx L Band Frequency from MODEM MHz 1200
C MUX Band - Tx Frequency (@ Multiplexed highest frequency) MHz 4500
Which LMR Cable Type ? (400 or 600) 600
B to C ADE to BDE LMR Cable length Meter 50.0
B to C Derived Cable Attenuation (according to length and LMR Type 400 or 600) dB -11.4
BDMx Tx Attenuation Selector (0dB or -15dB) dB 0
ADMx/BDMx Total Gain (Tx path) dB 19
Standard CCU Losses dB -4.0