Operation
−
45
−
Control of operation in FBL
Ⅱ
compatible mode
FWD input REV input STOP-MODE input Motor status
ON OFF − Clockwise rotation
OFF ON − Counterclockwise rotation
ON ON − Clockwise rotation
− − OFF Instantaneous stop
− − ON Deceleration stop
Speed characteristics
500
1000
1500
2000
2500
3000
0 20 40 60 80 100
500
1000
1500
2000
2500
3000
0 2 4 6 81 3 5 7 109
10 VDC
5 VDC
· External potentiometer position vs. speed
characteristics (representative values)
Motor shaft speed [r/min]
External potentiometer [position]
Motor shaft speed [r/min]
· External DC voltage vs. speed characteristics
(representative values)
External DC voltage [V]
SPEED-OUT output
12 pulses are output with each revolution of the motor output shaft synchronously with the motor operation (pulse
width of 0.5 ms).
Motor shaft speed (r/min) =
SPEED-OUT output frequency
12
× 60
SPEED-OUT output frequency (Hz) =
1
T
T
0.5 ms
Setting the acceleration time and deceleration time
Both setting ranges of the acceleration time and the deceleration time are 0.5 to 15 sec (at 3000 r/min).