Installation
16
5 Installation
5-1 Installation location
The motor and driver are designed and manufactured to be incorporated in equipment. Install them in a well-
ventilated location that provides easy access for inspection. The location must also satisfy the following conditions:
Inside an enclosure that is installed indoors (provide vent holes)
Operating ambient temperature: 0 to +40 °C [+32 to +104 °F] (non-freezing)
Operating ambient humidity: 85% or less (non-condensing)
Area free of explosive atmosphere, toxic gas (such as sulfuric gas), or liquid
Area not exposed to direct sun
Area free of excessive amount of dust, iron particles or the like
Area not subject to splashing water (rain, water droplets), oil (oil droplets) or other liquids
Area free of excessive salt
Area not subject to continuous vibration or excessive shocks
Area free of excessive electromagnetic noise (from welders, power machinery, etc.)
Area free of radioactive materials, magnetic elds or vacuum
Up to 1000 m (3300 ft.) above sea level
5-2 How to Install the motor
Combination type-parallel shaft gearhead
Secure the motor and gearhead through four mounting holes using the included mounting screw set.
Install so that there is no gap between the product and the mounting plate.
Hexagonal socket
head screw
Plain washer
Spring washer
MotorGearhead
(L2)
L1
Model Gear ratio
Hexagonal socket head screw
(Material: Stainless steel)
L2 [mm (in.)]
Tightening torque
[N·m (lb-in)]
Screw size L1 [mm (in.)]
BLMR5100
10
to
20
M8
70 (2.76) 11.5 (0.45)
12.0 (106)
30
to
100
85 (3.35) 13.5 (0.53)
BLMR6200
10
to
20
85 (3.35) 11 (0.43)
30
,
50
100 (3.94) 14 (0.55)
100
110 (4.33) 10 (0.39)