How to use MEXE02
−51−
3. Click "Yes."
Teaching/remote operation is enabled.
Teaching/remote operation requires synchronization of the data
under editing and the data of an applicable product. When the
data is not synchronized, the following window appears. Select a
synchronization method, and click "OK."
Note
When the above window appears, all the communications in progress will be OFF.
All the other monitors in progress in other windows are also stopped. Resume monitor after synchronization
is completed.
4. Execute teaching/remote operation using buttons in the window.
1 This is used to select the operation data number.
2 The motor rotates in the reverse direction.
3 The motor rotates in the forward direction.
4 This button is used to decelerate the rotating motor to a stop.
5 This button is used to accelerate the motor rotation speed.
6 This button is used to decelerate the motor rotation speed.
7 This is used to set the changed value in the rotation speed when pressing 5 or 6 once.
8 This is the operation data to be changed with the teaching function. The value can be changed directly.
9 This is the operation data presently written in the driver.
10
*
This is used to apply the data set with the teaching function as the digital setting value of the driver.
11 This button is used to stop the rotating motor instantaneously.
12
This is used to operate whether to release or hold the electromagnetic brake at motor standstill.
This is disabled while an alarm is present.
∗*
When applying the data set with the teaching function as the digital setting value of the driver, execute while the motor is in a
standstill state.
5. To exit the teaching/remote operation, unselect "Start the teaching remote operation."
If "Start the teaching remote operation" is unselected while the motor rotates, the following window appears.
Clicking "Yes" causes the motor to stop instantaneously.
Note
If the communication is disconnected while the motor rotates, the motor stops instantaneously.
5
3
98
1
10
7
42
6
11
12