- 72 - - 73 -
3.8. Auto-Power Mode
- Conguration for automatic power on by AC power connection.
- It is available only on Power On (Operative) status.
- CMD: 0x62(On), 0x63(Off)
- Send to MPDP
A. Normal Command
STX CMD Length
Data
ETX
ID Master
Value 0x02 Variable 0x02 Variable 0X01 0x03
* ID range(Program): 0x01(1) ~ 0xFF(255)
B. Broadcast Command
STX CMD Length Data: ID ETX
Value 0x02 Variable 0x01 0x00 0x03
* All PDP will do the same operation simultaneously. But, there will be no return communication. (One way command)
- Receive from MPDP
STX CMD Length
Data
Check Sum ETX
ID Master
Value 0x02 Variable 0x02 Variable 0X01 Variable 0x03
* ID range (Program): 0x01(1) ~ 0xFF(255)
* Check Sum: execute "Not" operation after adding all the values in "STX~Data" area..
3.9. DTV Over-Scan On/Off
- Users can select Over-scan when input is DTV resolution from DVI. It is only available with DVI mode.
- CMD: 0xE4(On), 0xE5(Off)
- It is usable only at Power on status.
- Send to MPDP
A. Normal Command
STX CMD Length
Data
ETX
ID Master
Value 0x02 Variable 0x02 Variable 0X01 0x03
* ID range(Program): 0x01(1) ~ 0xFF(255)
B. Broadcast Command
STX CMD Length Data: ID ETX
Value 0x02 Variable 0x01 0x00 0x03
* Make all PDP do the same operation. But, there will be no return communication. (One way command)
- Receive from MPDP
STX CMD Length
Data
Check Sum ETX
ID Master
Value 0x02 Variable 0x02 Variable 0X01 Variable 0x03
* ID range (Program): 0x01(1) ~ 0xFF(255)
* Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.
3.10. Over-Temperature Shut-down Control
- Commands for automatic power off making MPDP set stand-by and OSD warning method, if IP board
temperature is 95˚C or higher.
- CMD
* 0x64(Over Temperature Shut-down Enable)
: In case IP board temperature is 95˚C or higher, display warning signal "High Temperature" in red for 1 minute at the lower left corner
of MPDP and power off automatically (Stand-by mode.)
* 0x65(Over Temperature Shut-down Disable)
: In case IP board temperature is 95˚C or higher, display warning signal "High Temperature" in red for 3 seconds at the lower left
corner of MPDP and repeat the warning every 60 seconds. (No automatic power off)
- It is available only on Power On (Operative) status.
- The initial conguration is "Over Temperature Shut-down Enable."
- Send to MPDP
A. Normal Command
STX CMD Length
Data
ETX
ID Master
Value 0x02 Variable 0x02 Variable 0X01 0x03
* ID range(Program): 0x01(1) ~ 0xFF(255)
B. Broadcast Command
STX CMD Length Data: ID ETX
Value 0x02 Variable 0x01 0x00 0x03
* Make all PDP do the same operation. But, there will be no return communication. (One way command)
- Receive from MPDP
STX CMD
Length
Data
Check Sum ETX
ID Master
Value 0x02 Variable 0x02 Variable 0x01 Variable 0x03
* ID range(Program): 0x01(1) ~ 0xFF(255)
* Check Sum: Add the sum from STX to Data and execute "Not" operation.
3.11. Test Pattern
- Command for checking the operating status with internal patterns
- It is available only on Power On (Operative) status.
- CMD: 0x57 (Red), 0x58 (Green), 0x59 (Blue), 0x5A (White), 0x5B (Screen)
- Send to MPDP
A. Normal Command
STX CMD Length
Data
ETX
ID Master
Value 0x02 Variable 0x02 Variable 0X01 0x03
* ID range(Program): 0x01(1) ~ 0xFF(255)
B. Broadcast Command
STX CMD Length Data: ID ETX
Value 0x02 Variable 0x01 0x00 0x03
* Make all PDP do the same operation. But, there will be no return communication. (One way command)