SECTION 400 (Version 3.0)
Issue 1 January 1990
DBS
FF-2 Trunk mode
FF2-(l- 32)#-16#-(0
or l)#
Call Diversion
(Trunk to trunk connection trunk setting)
tt is set whether or not an outside line can make a
trunk to trunk connection.
This function can be used at an extension where
trunk to trunk connection has been set in the
extension mode.
In addition, if the time set with the call
monitoring timer is exceeded, the call is
automatically cut off.
O#: Trunk to trunk connection not possible
l#: Trunk to trunk connection possible
FFZ-(1 - 32)#-17#-(0 - 9)#
Incoming ring signal pattern setting
The ring tone pattern for incoming calls can be
changed for each trunk port
If outside lines are assigned for use to each
individual, they will know who the call is for by
the ring tone pattern and this will facilitate
answering.
O#: lncominq rinq tone svnchronized
1#:3secON/l secOFF
2%:2secON/Zsec OFF
38: 1 set ON I1 set OFF
4#: 1 set ON / 2 set OFF
59: 1 set ON / 3 set OFF
6#: 0.5 set ON / 0.5 set OFF
b 7#: 0.5 set ON IO.5 set OFF
and O.Ssec ON 12.5 set OFF
8#:0.5secON/3.5sec OFF
9t: 1 set ON / 7 set OFF
FF2-(1-32)#-18#- (I- 15)#
-
Outside line
disconnectsignal
detection
timer
If the signal indicating that an outside line has
been disconnected during a outside call or while it
is on hold is received, or if the outside line has
been cut off, the system automatically cancels the
outside line call. However, as the call ends
automatically when the outside line is instantly cut
due to the conditions for the connected PBX, it is
accommodated by this setting.
The time from when it is determined that the call
has been disconnected orthat it has been disabled
to when the outside line call status is
automatically canceled can be set within the
range of 50 - 750ms.
(%&No detection (Keep the connection)
19:Dixonnection bythe morethan 50msrignal
2#:Dixonnection by the more than lOOms signal
3#:Disconnection by the more than 150ms signal
4b:Dixonnection by the more than 2OOms signal
S#:Disconnection bythe more than 250ms signal
6#: Disconnection by the more than 300ms signal
7#:Disconnection bv the more than 350ms siqnal
8#:Dixonnection by the more than 400ms signal
9#:Dixonnection by the more than 450ms signal
1 O#:Dixonnection by the more than 500mr signal
1 1 #: Disconnection by the more than 550ms signal
128:Disconnection by the more than 600ms signal
13#:Dixonnection bythe more than 650ms signal
14Y:Dixonnection by the more than 700ms signal
158:Disconnection bythe more than 750ms signal
-31-
\
x
41
3

Table of Contents