DBS
FF-2 Trunk mode
FF2-(l- 32)#-19#-(Hour - Minute)#
DISA start time setting
A
CO line can be assigned as a DISA (direct inward
system access) line for a specific period of time.
When the outside line is not activated by this timer
as a DISA line it can be used as a normal outside
line. This timer specifies the stating time for D&4.
The time entered is in 24 hour format with no
spaces between hour and minute.
JCONFl#: No startina time (DATA reset)
HHMM#:(OO-23,00-59) Enterthe time
FF2-(l- 32)C20#-(0 or l)#
DISA end time setting
This timer specifies the ending time for DlSk A
normal CO line can be assigned as a DISA (direct
inward system access) line for a specific period of
time. When the outside line is not activated as a
DISA line it can be used as a normal outside line.
The time entered is in 24 hour format with no
spaces between hour and minute.
JCONFj#: No end timi(DATA reset)
HHMM#:(OO-23,00-59) Enterthe time