1
1-465
1-14. Product Fiche
U-60PE1E5A
Average Heating Season (Mandatory)
Colder Heating Season (Optional)
kW
XY,Z
kW
XY,Z
SEER
X,Y
A ć¹¼ GA ć¹¼ G
kW
XY,Z
SCOP
X,Y
SCOP
X,Y
Indoor Unit
Outdoor Unit
A ć¹¼ G
kW
XY,Z
SCOP
X,Y
kWh/annum
XY
kWh/annum
XY
elbu
(-10°C)
kW
X,YZ
kWh/annum
XY
A ć¹¼ G
kWh/annum
XY
A
B
C
E
F
GH I
JD
J
J K
K
K
L
L
L
M
N
O P
Q
Warmer Heating Season (Optional)
S-60PU1E5A U-60PE1E5A A++ 6.0 7.4 65 - Ć ĆĆ 4.1 2047 53 67 0.00 - Ć Ć284 53 Ć A+ 6.0
6.4 328 57 65S-60PF1E5A U-60PE1E5A A++ 6.0 3.9 2154-ĆĆĆ Ć
S-60PN1E5A U-60PE1E5A A 6.0 5.5 381 60
57 67
65 - Ć Ć
ĆĆ0.00 -A 6.0
ĆĆ2061 60 67 0.00 - ĆĆ A 5.6 3.8
S-60PK1E5A U-60PE1E5A A++ 6.0 6.6 318 64 67 0.00Ć A 6.0 3.9 2154 6465 - Ć Ć -ĆĆĆ
S-60PT2E5A U-60PE1E5A A++ 6.0 - Ć Ć Ć6.8 309 56 65 56 67 0.00 -A+ 6.0 4.1 2049 Ć Ć Ć
A
ī
: Panasonic Corporation
B
ī
: Model Name
C
ī
: SEER Grading
D
ī
: SCOP Grading (Standard, mandatory)
E
ī
: SCOP Grading (Warmer, optional)
F
ī
: SCOP Grading (Colder, optional)
G
ī
: Design Load kW (round up to one decimal)
<Cooling>
H
ī
: SEER (round up to one decimal)
I
ī
: Annual Energy Consumption (rounded
<Cooling> up to the nearest integer)
J
ī
: Design Load kW (round up to one decimal)
<Heating>
K
ī
: SCOP (round up to one decimal)
<Heating>
L
ī
: Annual Energy Consumption (rounded up to
the nearest integer) <Heating>
M
ī
Sound Power level for all indoor units dB
(cooling)
N
ī
Sound Power level for all outdoor units dB
(cooling)
O
ī
Sound Power level for all indoor units dB
(heating)
P
ī
Sound Power level for all outdoor units dB
(heating)
Q
ī
backup heating capacity X,YZ kW
R
ī
name of refrigerant and GWP
R410A (GWP 1975)
S
ī
Refrigerant leakage contributes to
climate change. Refrigerant with lower
global warming potential (GWP) would
contribute less to global warming than a
refrigerant with higher GWP, if leaked to
the atmosphere. This appliance contains a
refrigerant ļ¬ uid with a GWP equal to 1975.
This means that if 1
kg
of this refrigerant
ļ¬ uid would be leaked to the atmosphere,
the impact on global warming would be
1975 times higher than 1
kg
of CO
2
, over a
period of 100 years.
Never try to interfere with the refrigerant
circuit yourself or disassemble the product
yourself and always ask a professional.
T
ī
Explanation on annual energy consumption
Energy consumption āXYZā kWh per year,
based on standard test results. Actual
energy consumption will depend on how the
appliance is used and where it is located.
SM830231-02īSingleī꬧å·.indbīīī465SM830231-02īSingleī꬧å·.indbīīī465 2014/09/19īīī13:22:252014/09/19īīī13:22:25