5-58
5
Replace the HIC PC board and operate the unit. (Apply putty and
screws must not be loose) Does it operate normally?
9-1
See what happens.
10-1
Yes
No
Replace the control PC board and operate the unit.10-1 See what happens.
9 Check the
HIC PC
boards
10 Check the
outdoor
unit main
PC board
(Check content of 7) The test check of the HIC board is only a check on the output level, so the input stage may not be working.
ā¢
With the filter board broken, alarm P16 may not be triggered.
ā¢
Measure with an analog tester. (Set to the k ohm range.)
ā¢
Measure the board by itself. (Remove wires connected from other parts.)
ā¢
Measure using IPM terminals.
Conforming part resistance value (measure with an analog tester)
ā¢
Excepting the parts of ā
value is ā0 = short-circuitā.
ā, it is acceptable if a small resistance value appears as a reference value unless the
ā¢
HIC board IPM Pass/Fail Tests
Tester terminals
-
Resistance value (ohm)
U
1 k to 5 k
V
1 k to 5 k
W
1 k to 5 k
U
1 k to 5 k
V
1 k to 5 k
W
1 k to 5 k
NU
5 k to 10 k
U
100 k to
V
100 k to
W
100 k to
P
100 k to
PNU+
Tester terminals
+
Resistance value (ohm)
PNU-
U
100 k to
100 k to
V
100 k to
W
100 k to
Excepting the parts of ā
value is ā0 = short-circuitā.
ā, it is acceptable if a small resistance value appears as a reference value unless the
ā¢
Tester terminals
-
Resistance value (ohm)
U
1 k to 10 k
V
1 k to 10 k
W
1 k to 10 k
U
1 k to 10 k
V
1 k to 10 k
W
1 k to 10 k
HIC-
5 k to 20 k
U
20 k to
V
20 k to
W
20 k to
HIC+
20 k to
HIC+ HIC-+
Tester terminals
+
Resistance value (ohm)
HIC+ HIC--
U
20 k to
20 k to
V
20 k to
W
20 k to