EYFR03 User Manual 50 of 110 v1.6.0
Chapter 4: 20 January 2020
Example:
*%07%GU49CN53%*
8. Identifier part 4
This command sets the Identifier part 4 (VIN characters 76-100) reported by the unit in
tightening result messages and the ACOP MID 0152 Multiple identifier and result parts
notifications.
Data: up to 25 characters
Example:
*%08%RU39CN53%*
10. Reset batch count
This command resets the count of all currently running parameters on the unit.
Data: none
Example:
*%10%%*
To reset the batch count of a single parameter when running a group with multiple parameters,
use command 30. Reset parameter batch count.
11. Start Parameter
This command instructs the unit to start a parameter. Any other running parameter, group, or job
will be stopped before starting the new parameter.
Data: number of up to 3 digits specifying the parameter number to select (1-100)
Example:
*%11%73%*
This bar code would select parameter 73.
12. Start Group
This command instructs the unit to select a group. Any other running parameter, group, or job
will be stopped before starting the new group.
Data: number of up to 3 digits specifying the group number to select (1-100)
Example:
*%12%26%*
This bar code would select group 26.
13. Stop
This command instructs the unit to stop any running parameter, group, or job.
Data: none

Table of Contents