EYFR03 User Manual 80 of 110 v1.6.0
Chapter 7: EtherNet/IPTM 20 January 2020
Controller Settings Object
Class Code: 68 Hex
The Controller Settings Object represents the qualifier level settings for the EYFR03.
Class Attributes
ID
Access
Name
Data Type
Description of Attribute
Semantics of Value
1
Get
Revision
UINT
Revision of this object
1
Instance Attributes
ID
Access
Name
Data Type
Description of Attribute
Semantics of Value
1
Get
Radio Address
UINT
The radio address of the
device
2
Set
Radio Channel
USINT
The radio channel on which
the device is operating.
Range: 1-12
Changing this value will
require all tools to be
reassociated.
3
Set
Beeper Setting
BYTE
Controls when the unit will
sound the beeper
Bit 0 – Beep on batch
Bit 1 – Beep on reject
Bit 2 – Beep on cycle
4
Set
Beeper Volume
USINT
Volume level of the beeper
Range: 0-10
0 disables the beeper
5
Set
Batch Timeout
ITIME
Duration to show the batch
indicator on screen.
If 0, the indicator does
not clear timeout.
Cannot be negative
6
Set
Cycle Timeout
ITIME
Duration to show the cycle
indicator on screen.
If 0, the indicator does
not clear timeout.
Cannot be negative
7
Set
Reject Timeout
ITIME
Duration to show the reject
indicator on screen.
If 0, the indicator does
not clear timeout.
Cannot be negative
8
Set
NOKs
USINT
How the system handles
NOK results or rejects.
0 – Ignore
1 – Display
2 – Report
3 – Count
9
Set
Time
DT
The current system time of
the device.
10
Set
Name
SHORT_STRING
The name of the device
Maximum length: 25
Services
Service
Code
Available in
Service Name
Description of Service
Class
Instance
0x0E
Yes
Yes
Get_Attribute_Single
Returns the contents of the specified attribute
0x10
No
Yes
Set_Attribute_Single
Modifies a single attribute