EYFR03 User Manual 87 of 110 v1.6.0
Chapter 7: EtherNet/IPTM 20 January 2020
2 – Job
Ignored if Multi-Number is 0.
Status of up to 16 parameters currently running.
Parameter number currently using the tool. (0 means no parameter using the
tool is running.)
Number of results performed in the current batch for the tool.
Number of results required for a batch in the tool.
Status of tool
0 – None
1 – Cycle
2 – Batch
3 – Reject
4 – Batch NOK (batch complete with a counted reject)
Number of multi-parameter operation (job or group) currently running.
Ignored if 0.
Type of multi-parameter operation currently running:
1 – Group
2 – Job
Ignored if Multi-Number is 0.
Indicates if the qualifier is suspended.
0 – None/In Progress
1 – Complete
When running an individual Parameter (Multi Number = 0), Complete will
correspond to a batch completion.
When running a Group (Multi Number non-zero, Multi Type = 1),
Complete will happen when the last parameter in the group to completes its
batch.
When running a Job (Multi Number non-zero, Multi Type = 2), Complete
will happen when the last step (parameter or group) in the job is completed.
Padding byte for devices requiring even connection point sizes.
Total size: 85-86 bytes
Input Connection Points for Last Tightening Data (fixed length)
The connection points in this group will contain data about the last tightening. As such, they are
not updated after a parameter, group, or job selection until a tightening occurs. These points are
similar to the points in the 11x range, except that the SHORT_STRING fields are now fixed-
length character arrays. Strings shorter than the field length are left-aligned in the field and null-
padded.
130
ID number of the last tightening
Timestamp of the last tightening
Sequence number of the running multi-parameter operation.